An Optimal Combination of Invasive and Noninvasive Ventilator :-
As noninvasive ventilation, it is used increasingly in a wide range of clinical situations, we offer a dual solution AN359 which combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU
Ventilation Modes :-
VCV(A/C), PCV(A/C), PRVC, SIMV(VCV)+PSV, SIMV(PCV)+PSV, SIMV(PRVC)+PSV, SPONT/CPAP +PSV, BIVENT +PSV, NIV/CPAP, NIV-T, NIV-S/T
Parameters :-
Tidal Volume:20~2000 ml
Respiration Rate:1~80 bpm
Tinsp:0.2~9 s
Tpause:0~4 s
I:E Ratio:1:10~4:1
Tslope:0~2 s
Trigger Sensitivity:0~35 cmH2O
FiO2: Pressure (-20~0 cmH2O, above PEEP), Flow (0.5~20 LPM)
PEEP:
Psupport: 0~70 cmH2O
Pinsp:5~70 cmH2OMonitoring
Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP
Time Value:ftotal,fspont, I:E
Real Time Curves:Pressure-Time, Flow-Time, Volume-Time waveforms, Pressure-Volume, Volume-Flow, Flow-Pressure loops
Gas Monitoring: FiO2, ETCO2
Volume / Flow Value: Vti, Vte, MV, MVspont
Calculated Values: Compliance(C), Resistance(R) MVleak, RSBI, WOB, PEEPi
Alarm:-
Low Battery Air /O2 supply down High/Low PEEP
Paw high/low MVe high/low Circuit disconnnect
FiO2 high/low Inspiration/Expiratory tidal volume low
High Respiration Rate Apnea AC Failure Nebulizer On
Leakage out of range Occlusion
Technical Data :-
Power Supply: AC100~240 V, 50 Hz/60 Hz
Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port
Screen:12〞TFT color touch screen (detachable)
Supply Gas:O2, 0.28~0.6 MPa
Dimension (Width x Depth x Height):322 mm x 375 mm x 366 mm (Main Unit), 547 mm x 675 mm x 950 mm (Cart)
Weight:12.5 kg (Main Unit), 25 kg (Cart)
Superior Mobile ICU ventilator :-
Compact, big capacity battery, no air compressor, intra-hospital mobility
Comprehensive ICU ventilator including BIVENT and PRVC
Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution:-
Unique metal-based, autoclavable, heated exhalation valve
Built-in flow sensor, non-consumable design
Upgradeable ventilation system software, with an available USB port
The Unique Leak Compensation System – Keep precise control on the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically
Optimal patient-ventilator synchrony, increase patient comfort
Advanced Trigger Technique – Enhance sensitivity, avoid spurious triggering
Safe Ventilation Through Whole Treatment Phase Initial Treatment Phase
Noninvasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection
Preset patient’s height and IBW. Reduce clinician’s workload
Stable Condition Phase :-
Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant
Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition
PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation
Weaning Phase :-
Various ventilation modes enhance the weaning process
The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery
RSBI and WOB provide accurate reference for weaning
Rehab Phase :-
Data export port provides connection to hospital monitors and Patient Data Management Systems
Provides pressure support for the patient when spontaneous breathing is present
-